ETFE UL 10086 AWG 14 - 2 200°C 600V
Insulation material Fluoropolymer ETFE
Tinned flexible copper conductors
Temperature range -70°C to 200°C
Spark Test 6Kv
Rated voltage 600V
Test voltage 2 Kv x 1 min
Produced and printed according to E472542 UR UL 10086 200°C 600V VW-1
Reference UL 10086, UL 758, UL 1581
Using internal wiring
AWG | outer diameter mm | dam thickness mm minimum - Ø | construction | resistance at 20°C Ohm/km | articlenumber |
---|---|---|---|---|---|
14 | 2,40 +/- 0,1 | 0,228 - 0,254 | 19 x 0,38 | 8,96 | 5625514010 |
16 | 2,40 +/- 0,1 | 0,228 - 0,254 | 19 x 0,32 | 14,6 | 5625516010 |
18 | 1,69 +/- 0,05 | 0,228 - 0,254 | 19 x 0,25 | 23,2 | 5625518010 |
20 | 1,42 +/- 0,05 | 0,228 - 0,254 | 19 x 0,19 | 36,7 | 5625520010 |
22 | 1,25 +/- 0,05 | 0,288 - 0,254 | 7 x 0,25 | 59,4 | 5625522710 |
22 | 1,27 +/- 0,05 | 0,288 - 0,254 | 19 x 0,16 | 94,2 | 5625522010 |
24 | 1,10 +/- 0,05 | 0,228 - 0,254 | 19 x 0,13 | 94,2 | 5625524010 |
- Weitere Anfertigungen auf Anfrage
- Alle Angaben ohne Gewähr
- Sollten Sie Fragen zu diesem Produkt haben, können Sie uns gerne telefonisch oder über unser Kontaktformular erreichen.