Aquamate - round cables for waste water immersion

Construction

  • Conductor:               Bare cooper complying with CEI EN 60228
                             Class 5
  • Core insulation and
    identification:          XLPE
                             Up to 5 cores according to HD 308 S2
                             From 6 cores black numbered with green/yellow
                             (VDE 0293-JZ)
  • Jacket:                  CPE elastomer
                             Colour black RAL 9005

 

Technical Data

  • Operating voltage:       0,6/1kV
  • Insulation resistance:   > 200 MΩ.Km
  • Operating temperature:     
       - Fixed application:  - 40°C to 85°C
       - Min. Installation
         temperature:        - 25°C
       - Max. temperature
         in water:           + 40°C
       - Max. temperature
         on conductor:       + 90°C
  • Maximum tensile force:
       - Fixed application:  4 x outer diameter
       - Flex. application:  6 x outer diameter
  • Min. bending radius:
       - Fixed application:  5 x outer diameter
       - Flex. application:  6 x outer diameter

 

Properties

  • Resistance to mineral oils:  According to EN 50363-2-2
  • Resistance to water:         According to AD8
  • Constructions standards:     EN 50525-2-21,
                                 IEC 60502-1, EN 50363
  • UV resistant

cores x cross-section [mm] nominal diameter [mm +/- 5%] Cu-Weight [Kg/km] cable mass [Kg/km] Article Number
1x1,5 5,8 15 43 6505011510
2x1,5 9,2 28,8 114 6505021510
3G1,5 9,7 43,2 111,5 6505031510
4G1,5 10,6 57,6 136,5 6505041510
7G1,5 15,1 101 280 6505071510
12G1,5 18,3 173 420 6505121510
18G1,5 21,4 260 593 6505181510
24G1,5 25 346 785 6505241510
  • Other formats available on request
  • All data and products subject to change
  • If you have any questions regarding this product, please feel free to call us or drop us a message via the contact form.

Download datasheet