Description
Power and control cable for fixed installation in the following applications:, For indoor and outdoor use, In concrete with a temperature below the maximum cable operating temperature of +70°C according to the VDE standard HD 603/VDE 0276-603 - part 3-G (point 4) governing PVC cables for direct burial, Burial without additional, suitable underground protection according to VDE standard HD 603/VDE 0276-603 - Part 3-G (point 4) governing PVC cables for direct burial: Normal minimum installation depth 0.6 m, but at least 0.8 m under roads, Concentric copper conductor above all as PE, Easier connection due to the waveform of the concentric copper conductor, Bare copper wire conductor, PVC-based core insulation, Filling compound over the core assembly, Outer sheath based on PVC, Concentric, wave-like, outer conductor made of bare copper wires with inductance-reducing, cross-conductive copper bond double helix, Abbreviations "re", "rm", "se", "sm": r = round conductor form; s = sector-shaped conductor; e = single-wire conductor; m = multi-wire conductor;, HD 603/VDE 0276-603 for NYCWY with 3 or 4 cores and the relevant concentric protective conductor, Current load capacity according to HD 603/VDE 0276-603, part 3-G, table 14 (buried at +20°C ground temperature according to HD 603/VDE 0276-603, part 3-G, point 5) for routing underground and table 15 (in the air at an air temperature of +30°C according t, Flame-retardant according to IEC 60332-1-2,
| Specification | Value |
|---|---|
| Nominal cross section conductor | 35 |
| Core insulation | PVC |
| Core identification | Colour |
| Flame retardant | In accordance with EN 60332-1-2 |
| Nominal voltage U | 1 |
| Colour outer sheath | Black |
| Material outer sheath | PVC |
| Conductor category | Class 2 = stranded |
| Protective conductor | No |
| Operating temperature, flexible | - - - |
| Operating temperature, fix | -40 - 70 |
| Nominal voltage U0 | 0.6 |
| Screen | No |
| Number of cores | 4 |
| Halogen free (acc. EN 50267-2-2) | No |
| Max. conductor temperature | - |
| Outer diameter approx. | 29 |
| Low smoke (acc. EN 61034-2) | No |
| Conductor material | Cu, bare |
| Armouring | No |
| Lead sheath | No |
| Drain wire | No |
| Circuit integrity | No |
| Shape of conductor | Sector-shaped |
| Nominal cross section concentric conductor | 16 |
| Insulation integrity | No |
| Concentric conductor | Cu |
| Nominal cross section pilot/reduced core | - |
Product images